I.Features
1.The valve is used to remote control the
pressure of air channel. Control the outlet pressure of the
master valve by regulate the pressure of control vent.
2.Has overflow mechanism.The overflow valve
begin to exhaust automatically when the output pressure exceed
the certain pressure and keep the pressure changeless.
II.Symbol

III.Model
code

IV.Parameter
|
model
|
PJX
|
|
diameter mm
|
8
|
10
|
15
|
20
|
25
|
|
pressure range
(MPa)
|
0.05---0.8
|
|
pressure charatcter
(MPa)
|
0.02
|
|
temperature °C
|
5---60
|
V.Appearance and
installing

|
diameter
|
M1
|
M2
|
A |
B |
C
|
|
10(8)
|
G3/8"(G1/4")
|
(M12*1.25)
|
M18*1.5
|
G1/8" |
80 |
84 |
76 |
|
15
|
G1/2"
|
--
|
M22*1.5
|
G1/8" |
80 |
91.5 |
72 |
|
25(20)
|
G1"(G3/4")
|
(M27*2)
|
M33*2
|
G1/8" |
120 |
111 |
109 |
|
40
|
G11/2"
|
-- |
M48*2
|
M10*1 |
120 |
145 |
136 |
|
50
|
G2"
|
-- |
M60*2
|
M10*1 |
120 |
150 |
148 |
|
80
|
--
|
-- |
ZG3"
|
M10*1 |
165 |
230 |
292 |
|